Address:
264 Camino Bailen, Escondido - Fire Zone (within 1 mile)
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
2163'
Required Method:
1/150
Calculation:
2163 ÷ 150 = 14.42 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
14.42
Calculation:
14.42 x 144 = 2076.48 sq. in of Code Required Ventilation
Square Inches Provided:
(22 x 97.5) = 2145 sq. in
Square Inches Needed:
14.42 x 144 = 2076.48 sq. in
Where do I install vents graphic
Vent Placement
High / Exhaust Vents Needed:
11
Low / Intake Vents Needed:
11
Total Vents Needed:
22
concrete Tile Vents
High Profile (S)
NET FREE VENTILATION AREA
Wire Mesh 97.5 sq. in
Figures based on independent evaluation reports.
Tile Roof Drawing