Address:
4985 Broadlake Vw, Colorado Springs, CO 80906: Area 4 Lower Left
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
298'
Required Method:
1/300
Calculation:
298 ÷ 300 = 0.99 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
0.99
Calculation:
0.99 x 144 = 142.56 sq. in of Code Required Ventilation
Square Inches Provided:
(2 x 86.25) = 172.5 sq. in
Square Inches Needed:
0.99 x 144 = 142.56 sq. in
Where do I install vents graphic
Vent Placement
High / Exhaust Vents Needed:
1
Low / Intake Vents Needed:
1
Total Vents Needed:
2
clay Tile Vents
Medium Profile (M)
NET FREE VENTILATION AREA
Tile Profile Medium (M)
Wire Mesh 86.25 sq. in
Figures based on independent evaluation reports.
Tile Roof Drawing
Questions?